| Specifications |
| Voltage DC |
| Accuracy* |
± (0.025%+5) |
| Max. Resolution |
1 µV |
| Maximum |
1000 V |
|
| Voltage AC |
| Accuracy* |
± (0.4%+40) |
| Max. Resolution |
1 µV |
| Maximum |
1000 V |
|
| Current DC |
| Accuracy* |
± (0.15%+2) |
| Max. Resolution |
0.01 µA |
| Maximum |
10 A |
|
| Current AC |
| Accuracy* |
± (0.75%+5) |
| Max. Resolution |
0.01 µA |
| Maximum |
10 A |
|
| Resistance |
| Accuracy* |
± (0.05%+2) |
| Max. Resolution |
0.01 Ω |
| Maximum |
500 MΩ |
|
| Capacitance |
| Accuracy* |
± (1.0%+5) |
| Max. Resolution |
1 pF |
| Maximum |
50,000 µF |
|
| Frequency |
| Accuracy* |
± (0.005%+1) |
| Max. Resolution |
0.01 Hz |
| Maximum |
1 MHz |
|
| Temperature |
| Accuracy* |
± (1.0%+1°C) |
| Max. Resolution |
0.1°C |
| Range |
-200°C to 1350°C |
|
| Conductance |
| Accuracy* |
± (1%+10) |
| Max. Resolution |
0.01 nS |
| Maximum |
500 nS |
|
| dBm and dBV |
| Accuracy* |
± 0.1 dB |
| Max. Resolution |
0.01 dB |
| Range |
-52 to 60 dB |
|
| Note |
| * |
Accuracies are best accuracies for each function |
|