| Fluke 73/77 Series III Digital Multimeter |
 |
| Specifications |
| Voltage DC |
| Maximum Voltage: |
|
|
Fluke 73: 600V
|
|
Fluke 77: 1000V |
| Basic Accuracy:
|
0.3%
|
| Maximum Resolution:
|
0.1 mV
|
| | Voltage AC |
| Maximum Voltage: |
|
|
Fluke 73: 600V |
|
Fluke 77: 1000V |
| Basic Accuracy:
|
2% |
| Maximum Resolution:
|
1 mV |
| | Current DC |
| Maximum Current: |
10 A |
| Maximum Resolution:
|
0.01 mA |
| Basic Accuracy: |
1.5% |
| | Current AC |
| Maximum Current: |
10 A |
| Maximum Resolution: |
0.01 mA |
| Basic Accuracy: |
2.5% |
| | Resistance |
| Max Resistance:
|
32 M½ |
| Basic Accuracy:
|
0.5% |
| Maximum Resolution:
|
0.1 ½ |
|
| Environmental Specifications |
| Operating temperature | | | Storage temperature | | | Humidity (Without Condensation) |
|
0% - 90% (0¡C - 35¡C) |
|
0% - 70% (35¡C - 50¡C) |
| | Operating Altitude | |
| Safety Specifications |
| Overvoltage category |
| Fluke 73 III: |
EN 61010-1 to 600 V CAT II |
| Fluke 77 III: |
EN 61010-1 to 600 V CAT III/1000V CAT II |
| | Agency Approvals | |
| Mechanical & General Specifications |
| Size |
| Fluke 73 III: |
166 x 75 x 28 mm |
| Fluke 77 III: |
190 x 89 37 mm |
| | Weight |
| Fluke 73 III: |
340 g |
| Fluke 77 III: |
365 g |
| | Warranty | | | Battery life |
| Alkaline: |
~2000 hours typical |
| | Shock & Vibration |
|
Per MIL-T-PRF 28800F Class III |
|
|
|
 |
| Back to Fluke 73/77 | |
|